Detailed description page of SalivaDB

This page displays user query in tabular form.

SAL_25262 details
Primary information
SALIDSAL_25262
Biomarker nameSPRR3
Biomarker TypeNA
Sampling MethodCollected from six volunteers of between 20 and 40 years old.
Collection MethodThe pooled saliva was then expectorated into a 50 mL Falcon tube. Collected saliva was then frozen on dry ice and transported to the laboratory.
Analysis MethodRTLAMP
Collection SiteWhole Saliva
Disease CategoryHealthy
Disease/ConditionHealthy
Disease SubtypeNA
Fold Change/ ConcentrationNA
Up/DownregulatedNA
ExosomalNA
OrganismHomo sapiens
PMID30058014
Year of Publication2018
Biomarker IDSPRR3
Biomarker CategoryGene
SequenceGACCAGATCCCAGAGGCTGAACAGCTCGACCTTCTCTGCACAGCAGGTGTGGAACTTAGGATCAGAAAAGGCGAGTGATTTCTGTAAAGGCTTGCTAAGTTAGCAAGACAATATACCCACTTCAAGAGCACTCTCCTGTCAACATGTATTGAAAATTTTTAATATAGAAGGCACTACATTGGCAATTTTGATGATCAAAAGATAAGTTTTTCTTTATTGCATGAATGTATAATCCATTAGAAAACATATACTTGACTAAAATTTGCAAACATACAGCATGGGGAGTGATTAGCAGAGAGGGAAAGCAAGTATCATGCTGTGGCAAAACGAGGAAGGTGAGAGCATCAGGGAGGACAGCCATGAGAGGTGGGCATGTGTGGGGAGGCAGCGATGATGTGGAGAGCCTGCCAGAGAGCATGTGCAGCAGGCACAGTGTGAACAGAGGCTCCCAGGTGGATTGTGGGAGCCTTAGGGGGAAGTTTAGATAAGAGTTCTCCTGGGAGAACTATCGCACTCTATAAGGAGGACATGAGTGAGTAGATTCTAGACTGCTGACCTTAAAATCTTTCCAACTTATGGAAAAACTGAGGTGTCACATCAATCTTCAGCCAATGACACACAGCCAAGAGTGGTATTAAAAGTGATTTAATCAGGGCAGAGCAAGAAACATGCATTTCTTTTCACTCAATTCCTCAGATGAACCCTGAGCAGCTGAAGACCAGAAAAGCCACTATGACTTTCTGCTTAATTCAGGAGCTTACAGGATTCTTCAAAGAGTGTGTAAGCGAAAGCTTCAGAGTATATATTTGCATATTTGTATGTGTTTTCATGTTGTACGTAGGTTTTTAGATGTACCAGAAAGAAAAGAAGCATAAAGAAAGGCTCCATTTACACAATGTGGAAGAAATCAACTTTACCTTATTCTCTGGAAGATAAGTGGGGATCACCAAAGCATCCCATGATCTCAAATTCAGGGAAAAAGAAAGAAAAGAGAGGCTCTCAGTTCTGAAGGAGAATGAAATGACAGATATTTGTCATTAAACTGGGCTTCATTCCTACTTAATCAAAGCACTGAATTAGCTGTTTTGTCTCTAGGTCCAGCATCCTTTGAAACATGAGTTCTTACCAGCAGAAGCAGACCTTTACCCCACCACCTCAGCTTCAACAGCAGCAGGTGAAACAACCCAGCCAGCCTCCACCTCAGGAAATATTTGTTCCCACAACCAAGGAGCCATGCCACTCAAAGGTTCCACAACCTGGAAACACAAAGATTCCAGAGCCAGGCTGTACCAAGGTCCCTGAGCCAGGCTGTACCAAGGTCCCTGAGCCAGGTTGTACCAAGGTCCCTGAGCCAGGATGTACCAAGGTCCCTGAGCCAGGTTGTACCAAGGTCCCTGAGCCAGGCTACACCAAGGTCCCTGAGCCAGGCAGCATCAAGGTCCCTGACCAAGGCTTCATCAAGTTTCCTGAGCCAGGTGCCATCAAAGTTCCTGAGCAAGGATACACCAAAGTTCCTGTGCCAGGCTACACAAAGGTACCAGAGCCATGTCCTTCAACGGTCACTCCAGGCCCAGCTCAGCAGAAGACCAAGCAGAAGTAATTTGGTGCACAGACAAGCCCTTGAGAAGCCAACCACCAGATGCTGGACACCCTCTTCCCATCTGTTTCTGTGTCTTAATTGTCTGTAGACCTTGTAATCAGTACATTCTCACCCCAAGCCATAGTCTCTCTCTTATTTGTATCCTAAAAATACGTACTATAAAGCTTTTGTTCACACACACTCTGAAGAATCCTGTAAGCCCCTGAATTAAGCAGAAAGTCTTCATGGCTTTTCTGGTCTTCGGCTGCTCAGGGTTCATCTGAAGATTCGAATGAAAAGAAATGCATGTTTCCTGCTCTGCCCTCATTAAATTGCTTTTAATTCCAAGAAAAAAAAAAAAAAAAAA
Title of studyThe detection and identification of saliva in forensic samples by RT-LAMP
Abstract of studyWe report on a novel method for saliva identification by reverse transcription-loop-mediated isothermal amplification (RT-LAMP). In our previous report, real-time RT-LAMP was used for blood identification by using HBB detection as a model but in this advanced study, this method was refined for the identification of the more challenging body fluid of saliva. Expression of the18S rRNA gene was used as the internal control and the Statherin (STATH) gene as the saliva-specific marker. A turbidimeter was used for real-time detection of the RT-LAMP products, and confirmation was obtained that the real products were generated using: agarose gel electrophoresis, calcein fluorescence detection and/or enzymatic digestion. The specificity of the test was performed using 42 samples including 7 different body fluids, and the expression of STATH was only observed in all the saliva samples (6) with a threshold time of 39.4 ± 2.9 min. Sensitivity testing showed that RT-LAMP products for STATH were stably detected when the RNA template was not less than 6.25 ng. When the primer concentrations for STATH were two times that of 18S rRNA, saliva could be identified in the body fluid mixtures even at a ratio (saliva:semen) of 1:3 (without loop primer)/1:5 (with loop primer). A multiplex RT-LAMP was established to simultaneously amplify the 18S rRNA and STATH genes, and applied to the identification of saliva on ten non-probative cigarette butts. A positive result for saliva was obtained from all ten butts, even for those that returned a negative or ambiguous result using the amylase test. A direct RT-LAMP test is also reported where the RNA extraction step was omitted to speed the collection of data and all tests using either the simplex or multiplex RT-LAMP resulted in a positive response if saliva was present. Our data provide a simple and effective means to detect the presence of saliva.