Structure Checker is a chemical validation tool detecting and fixing common structural errors or special features that can be potential sources of problems. The Structure Checker wizard is a desktop application for the batch checking and fixing structures of input file(s). Your large files (like SDfiles) are scanned for drawing errors or features you want or don't want to include in the file. This application offers manual operation mode displaying the compounds having errors and allowing the manual modification. Additionally, automatic fixers are provided for many types of issues, and a validation report can be generated as well. For the more comfortable usage of Structure Checker, Profile manager is available to customize every step of the wizard.

Available checkers

See the detailed list of available checkers.

Structure Checker Graphical User Interface (GUI) user guide

General layout

Structure Checker

This chapter gives you a simple walkthrough of the usage of Structure Checker. The major steps are demonstrated on the screenshots of every page of the checking routine.

  1. Select input files:

    select input file

    In this step you define the files to be checked and fixed. Click on the Browse button on the right side to add files one by one; click on Add more files to add further files or multiple files at a time. Select one or more files (Shift or Ctrl + mouse click) and click Open. You can add unlimited number of files but remember, the output will be written to only one file.

    To remove a file from the list, click on remove file button in line with file.

    Click Next to proceed to the next step.

  2. Create checklist:

    create checklist

    In this screen you can see two panels. On the left, all available checkers are listed in alphabetical order. For creating your checklist, just select the actions you want to perform and click Add button to transfer it to your checklist, i.e., into the right panel.

    You can create an ordered list of checkers by moving the selected item(s) with the up or down arrow next to the right panel.

    arrange list

    Removal of check elements from the checklist is similarly easy: click the items in the right panel and click Remove button between the two panels. Click on Remove All at the bottom of right panel if you want to remove all elements from the checklist.

    If you'd like to use this checking configuration later, export it to a configuration file by clicking Export... button. Browse to the location and name the file in the Save dialog window.

    To load a configuration file, click the Import... button. Browse to the location in the Open dialog window.

    save confiuration

    Some checkers have options to refine the issue detection. These options appear when you click on the checker in the right panel of the configuration page.

    set checker option

    Fixer can also be configured for each checker, i.e., what to do when an issue is found. Apart from Manual fix and keeping the compounds unfixed, Do not fix, one or more automatic fixers are also available as Fix option.

    Click Next to proceed.

  3. Set options:

    set options

    Operation mode

    Report options

    Each error and issue is recorded in the report logged during the checking and fixing procedure.

    Click Next to proceed.

  4. Specify output:

    specify output

  5. Run Structure Checker:

    summary

    In this page, you can see the confirmation of input and output files, operation mode, and report options before starting the checking/fixing process. To change any of these settings:

    navigate back

    To perform structure check, click Run.

    manual fix

    If you have chosen a mode which prompts you to fix manually the structures, a MarvinSketch window is displayed with the incorrect structure, and the Structure Checker side window shows you the source of the issues. Choose the fixing method by clicking on the checker, select the mode of fixing if applicable, and click Fix selected. After fixing the molecule, click on Accept button to accept the changes, or Discard, if you want to save the molecule with errors.

    result

    According to previously set checking procedure, Summary window displays the checking and fixing results in different tabs.

    tabs1 or tabs2

Preferences

You can reach the following actions via Preferences button:

Profiles

Using profiles, the checking routine can be simpler and easier. Besides the two read-only profiles, "Blank" and "Last Used", custom profiles are also available to set and use.

You can add, set custom profiles, and select the default one (used at start-up) by clicking on the Preferences button > Profile...> Edit Profiles... Unless default profile is selected, Blank profile is loaded at start-up.

How to set and configure a custom profile

 